Septic Tank AdviceDesign, sizing and installation

How Far Should a Septic Tank Be From a House?

Published
Updated
Reading time
4 min

Request a quotation

If you’d like a quotation, we’d love to hear from you. Please leave us your details below and we’ll come back to your at the earliest opportunity. Thank you!

    In this guide

    The short answer

    In England a septic tank should be at least 7 metres from any habitable part of a building, and preferably downslope of it. The drainage field it feeds needs to be further away, at least 15 metres from any building. Both distances come from Approved Document H, the building regulations guidance for drainage, rather than from the Environment Agency.

    Twin tanks bedded in the excavation
    From an ADP jobTwin tanks bedded in the excavation

    Those two figures are the ones most people want, but there are several more that decide where a system can go on a plot.

    Distances for the septic tank

    Measured fromDistanceSource
    Habitable parts of any buildingAt least 7 metres, preferably downslopeApproved Document H, 1.16
    Vehicle access for emptyingWithin 30 metres, if the tank's invert is no more than 3 metres below the access levelApproved Document H, 1.17

    The 30 metre figure exists so a tanker hose can reach the tank. The route for the hose also has to avoid going through the house. A tank deeper than 3 metres below where the tanker parks needs to be closer.

    Habitable parts means rooms people live in. A detached garage or a shed isn't habitable, though it is still a building for the drainage field distance below.

    Distances for the drainage field

    Measured fromDistanceSource
    Any buildingAt least 15 metresApproved Document H, 1.27
    Any watercourse or permeable drainAt least 10 metresApproved Document H, 1.27
    Any point where groundwater is taken for supplyAt least 50 metres, and not in source protection zone 1Approved Document H, 1.27
    Other drainage fields and soakawaysFar enough apart that the ground is not overloadedApproved Document H, 1.27

    Approved Document H also keeps roads, driveways, paved areas and other underground services out of the drainage field area. And the groundwater should never rise to within 1 metre of the drainage pipes, which in practice decides how deep the field can go.

    Distances for a treatment plant

    Approved Document H says the discharge from a sewage treatment plant should be sited at least 10 metres from watercourses and any other buildings. Where the plant discharges to ground, the drainage field distances above apply. For a plant discharging to a stream, the general binding rules add their own conditions, which we cover in where does the water go from a sewage treatment plant.

    Distances in the general binding rules

    The Environment Agency's rules for England add distances that decide whether you need a permit at all.

    • A public foul sewer within 30 metres of the property boundary means a discharge started since 2015 cannot use the rules. For a development, the 30 metres is multiplied by the number of homes.
    • Anywhere within 50 metres of a private drinking water supply is treated as source protection zone 1, which needs a permit.
    • A new discharge since 2 October 2023 within 50 metres of another one under the rules needs a permit.
    • Discharges since 2015 can't be within 50 metres of certain protected nature sites.

    Our general binding rules guide explains each one.

    What about boundaries and trees?

    You will see fixed distances from boundaries and trees quoted online as rules. Approved Document H does not set them. Keeping a drainage field away from a neighbour's land and from tree roots is sensible design, and a council may have a view if planning permission is needed, but there is no national figure.

    Scotland, Wales and Northern Ireland

    Approved Document H applies in England. Wales has its own version of the building regulations, and Scotland and Northern Ireland have separate building standards with their own figures. If your property is outside England, check with the local building control team.

    What if an existing tank is too close?

    Many older tanks were installed before these distances applied and sit closer to the house. That is not automatically a breach. The building regulations apply to new work, so an existing system is judged against the rules of its time and the general binding rules. If you are replacing it, the new system will need to meet the current distances, which can mean moving it.

    We design new systems around these distances from the first site visit. See septic tank installation, or read designing a septic tank system for the full process. For the depth side of the question, see how deep is a septic tank.

    Checked against Approved Document H (2015 edition) and the GOV.UK general binding rules on 15 October 2026.

    Paul Pilling

    About the Author:

    Paul Pilling

    Director & Septic Tank Specialist

    Paul has over 20 years experience working in the waste water industry and as such he is well suited to provide expert advice and solutions to all your sewage needs.

    He began his career as a maintenance engineer working primarily on pumping stations. He then joined one of the largest manufacturers of sewage treatment plants as a maintenance engineer, progressing to Lead Engineer, before joining ADP Environmental Services.

    Every guide by Paul Pilling

    Sources this guide links to

    1. Approved Document Hgov.uk